Zum Inhalt springen
ENVIRONMENTAL SIMULATION & LABORATORY TESTING

Environmental and laboratory testing. Tested true to reality.

Complementing the EMC measurements, who offers comprehensive climate testing and thermography imaging — ideal for qualifying assemblies and devices under real-world environmental conditions.
Slide 1 of 2

Climate, thermography & lab

Three test areas with which we safeguard your assemblies under real-world conditions.

Climate testing

Temperature cycling tests (cold / heat)
Combined climate stress scenarios
Heat storage up to +250 °C

Thermography

Infrared thermography imaging of assemblies and circuits
Identification of hotspots and thermal weak points
Documentation for quality assurance and development optimization

Laboratory testing

Component failure testing
Insulation testing
High-voltage testing
EQUIPMENT

Our measurement equipment in detail

Professional equipment from reputable manufacturers, for precise and reproducible results.

Climate testing & temperature recording

DeviceSpecificationEquipment
Climate conditioning
Climate chamber−42 °C to +180 °C10–98 % RHInterior: 75 × 58 × 76 cmVC³ 7034Vötsch
Heat chamberup to +250 °C
Recording & analysis
Thermography320 × 256 pixels−25 °C to +135 °C (±5 %)A35FLIR
Temperature measurement60 channels−75 °C to +250 °CAlmemoAlmemo
Humidity measurement0–100 % RH (±8 %)
Thermocouples270 °C to 1,300 °C, type KIn-house productionwho

For standards including:

IEC 60068-2-1IEC 60068-2-2IEC 60068-2-14 IEC 60068-2-30IEC 60068-2-78

General electrical testing

DeviceSpecificationEquipment
Conditioning & signal generation
Mains simulation0–300 V / 0–6 A0–500 Hz3-phase mains simulation
Lab power supply30 V, 20 AEA-PS 3032-20 B
Signal generatorDC–15 MHz0–10 V into 50 ΩSine, Noise, Ramp, Square33120AAgilent
Measurement & analysis
Power analyzerup to 600 V AC (L–N)up to 7 A, phase angleUMG 508 / 512Janitza
Oscilloscope500 MHz, 2.5 GS/s10 M points4× analog + 16× digitalMSO 4054Tektronix
Multimeter0.1 V–750 V AC0.1 V–1,000 V DC0.1–3,000 mA AC/DC34410A Agilent2000 Keithley
Near-field probeEMC diagnosticsLanger EMV-Technik
Network analyzerup to 3.2 GHzSVA 1032XSiglent
Safety testing
Dielectric strength2,000 V DC / 600 V AC, 30 AGLP2eSchleich
Insulation measurement0–4 Ω, up to 1,000 V1000DMETRISO
Grounding / leakage current / insulationup to 19 Ω continuityup to 20 mA leakage currentup to 199 MΩ insulationMI 3309 DeltaGT ProMetrel

For standards including:

IEC 61000-3-2IEC 61000-4-11

Let's talk about your project.

Whether a concrete plan or a first idea — we're happy to advise you. In a non-binding initial conversation, we'll clarify together how we can support you.