EMC MEASUREMENTS
Our own EMC chamber. Maximum flexibility.
No waiting times.
Since 2019 we have operated a standard-compliant 3-meter fully anechoic chamber with modern measurement equipment — right at our site in Lübeck. For you that means: faster development cycles and early certainty for certification.
3 m
Fully anechoic chamber
Standard-compliant
6 GHz
Frequency range
Radiated measurements
30 V/m
Field strength
Per IEC 61000-4-3
Two ways to use our EMC chamber
Whether development-accompanying or as a standalone booking — you decide how to use our EMC chamber.
Development-accompanying measurements
As part of our customer projects, we carry out pre-tests during development. This way we identify interference sources early, instead of only discovering them at the final type test — saving time, money and nerves.
Book the chamber for your tests
Book our EMC chamber independently of a development project — for your own type tests and product qualifications. On-site we provide a soldering station, tools and filter components. Our experts are happy to support you with interference-suppression measures.
EQUIPMENT
Our measurement equipment in detail
Professional equipment from reputable manufacturers, for precise and reproducible results.
⚡
Conducted measurements
| Test | Specification | Equipment |
|---|---|---|
| Emission | ||
| Band A9–150 kHz | 230 V, 16 A | LISN C2-16Frankonia |
| Band B150 kHz–30 MHz | 230 V, 16 A | LISN C2-16Frankonia |
| Immunity | ||
| Band B151 kHz–230 MHz | 6 W (10 V at 230 MHz) | CDN M2-10kCDN S9-10k |
| Band B152 kHz–1 GHz | 100 W up to 100 MHz100 W (100–230 MHz)50 W (230 MHz–1 GHz) | EMCL-20 |
| Burst | 5.1 kV | IMU-MGSEMC Partner |
| Surge | 5.1 kV | IMU-MGSEMC Partner |
| ESD | 16 kV | IMU-MGSEMC Partner |
| Voltage dips | max. 5 A | IMU-MGSEMC Partner |
| Mains variation | 6 A | Mains simulation3-phase |
◎
Radiated measurements
| Test | Specification | Equipment |
|---|---|---|
| Emission | ||
| Band C30–300 MHz | 3-meter fully anechoic chamber | ERX-6Frankonia |
| Band D300 MHz–1 GHz | 3-meter fully anechoic chamber | ERX-6Frankonia |
| Band E1–6 GHz | 3-meter fully anechoic chamber | ERX-6Frankonia |
| Immunity | ||
| Band C30–300 MHz | 50 W (10 V/m)10 V/m @ 3 m30 V/m @ 1 m | FLL-75 |
| Band D300 MHz–1 GHz | 120 W (10 V/m)10 V/m @ 3 m30 V/m @ 1 m | FLH-200B1 |
| Band E1–6 GHz | 45 W (10 V/m) up to 3 GHz10 V/m @ 3 m / 30 V/m @ 1 m30 W (3 V/m) up to 6 GHz3 V/m @ 3 m / 10 V/m @ 1 m | FLG-70-CAFLG-30F |
| Magnetic fieldsPower-frequency | 10–400 Hz, up to 1,000 A/m | – |
Covered standards
IEC 61000-4-2IEC 61000-4-3IEC 61000-4-4
IEC 61000-4-5IEC 61000-4-6IEC 61000-4-7
IEC 61000-4-11EN 55011EN 55022
EN 50147-1CISPR 16-1-1CISPR 16-1-4
MIL-STD-461FMIL-STD-461GISO 11452-2/3/4/5
RS103
ADVANTAGES
Why measure at who?
No waiting times
Our own chamber means: appointments within a few days instead of weeks of lead time at external labs.
Iterative instead of one-off
Pre-tests during development. Detect problems, fix them and re-measure immediately — all on the same day.
On-site changes
Soldering station, tools and filter components are ready, so you can optimize directly on the test object.
Expert support
Our EMC specialists support interference-suppression measures and advise on standard-compliant design decisions.